TKMS Software Version History Rev 5.0 Decks can now be numbered from the bottom up or the top down. Rev 4.9 The numbers from the comparison tables are now used immediatly. Rev 4.8 The Administrator switch now has no timeout. A problem with recovering from paused data charting was fixed. The operator can now change product codes. When a reference switch is pushed, a reference calculation is only performed if (Current-Zero) > Zero/10. During referencing, the "Zero", "Master Zero", "Ref", and the "# Ref Samples" controls are disabled. During referencing the "Ref Plate Detected" LED lights . During referencing the "Finding Average" LED lights when each new sample is added to the average calculation. The "Shut Up" sensors button was removed. Many tables that were supposed to be read only now are. Rev 4.7 The Administrator switch now has a 15 minute timout. It only automatically switches to Operator mode when the program first starts. A problem with the damping calculations was fixed. The Enter key can now be used to enter the administrator password. The cursor is now automatically inserted into the password field. Rev 4.6 When a sensor is disabled, it's value is now excluded from the mean calculation. Rev 4.5 The Product Table now shows only the data for the correct number of concentrators. The Product Table now shows the concentrator number over the first column of the zine's data Rev 4.4 The damping now applies to the auxillary inputs. The wet end sensor input is input #64 in zone 1. The "Transfer Results Here" buttons are disabled unless there are results in the table. Rev 4.3 Some minor video issues were fixed. The Password button action was changed to make it easier to use. Gaps in the initialized chart data are now gaps in the charts. Rev 4.2 The installer now includes Zone Chart.txt and Multiplexers Backup.txt. Gaps in the initialized chart data are now gaps filled with a "2". Rev 4 The charts are now initialized from the Zone Chart.txt file according to the value in the "Chart History Length" field. Valid entries are 0.01 to 8 hours. The software may take several seconds to initialize each hour of history data. During this time it may appear locked up. The maximum size for the Zone Chart.txt file is now 2MB. Rev 3 The Disable Sensor controls now affect the Kiln Jam alarm. A bug affecting the Kiln Jam alarms for more than two sensors accross was fixed. REv 2 The Disable Sensor controls were added to keep out-of-range sensors from triggering the Sensor Alarm. The Alarms page was added under the Configuraiton tab. The individual sensor disable controls were added. Rev 1.51 The Enable Alarms button was added. Rev 1.50 The Operator/Administrator control and password function were added. The alarm aouput function was updated. The dates and times now follow the PC's configuration. Rev 1.41 The damping values are applied to each sensor instead of just the mean value.